BXHRG - SEMI-TRANSPARENT STAIN, A14
- MSDS: BXHRG
- Manufacturer: THE SHERWIN WILLIAMS CO
- Product Name: SEMI-TRANSPARENT STAIN, A14
- National Stock Number: 8010-01-397-3907
Product Identification
Product ID:SEMI-TRANSPARENT STAIN, A14
MSDS Date:03/01/1991
FSC:8010
NIIN:01-397-3907
MSDS Number: BXHRG
Responsible Party
CLEVELAND, OH 44115
US
Emergency Phone: 216-566-2917
Info Phone: 216-566-2902
Cage: DO693
Contractor
Telephone: 216-566-2902
Cage: DO693
Ingredients
MINERAL SPIRITS (VAPORS PRESSURE 2.0 MM HG)
CAS: 64742-47-8
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM
MINERAL SPIRITS, 140-FLASH (VAPOR PRESSURE 0.5 MM HG)
CAS: 64475-85-0
RTECS: PY8240000
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM
TALC
CAS: 14807-96-6
RTECS: WW2710000
OSHA PEL 2 MG/M3 RDUST
ACGIH TLV: 2 MG/M3 RDUST
ETHYLENE GLYCOL (VAPOR PRESSURE 0.1 MM HG) (<5% MAY BE
CAS: 107-21-1
RTECS: KW2975000
OSHA PEL C 50 PPM
ACGIH TLV: C 50 PPM
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
VOC 5.51 LB/GL
Hazards
Reports of Carcinogenicity:NTP:UNKNOWN IARC:UNKNOWN OSHA:NO
Health Hazards Acute and Chronic:IRRIT OF EYES, SKIN & RESPIRATORY
SYSTEM. MAY CAUSE NERVOUS SYSTEM DEPRESSION. EXTREME OVEREXPOSURE
MAY RESULT IN UNCONSCIOUSNESS, POSSIBLY DEATH. HEADACHE, DIZZY,
NAUSEA, LOSS OF COORDINATION ARE IND ICATIONS OF EXCESSIVE
OVEREXPOSURE TO VAPORS OR SPRAY MISTS. REDNESS, ITCHING, BURNING
MAY INDICATE EXCESSIVE EXPOSURE.
Explanation of Carcinogenicity:CRYSTALLINE SILICA IS LISTED BY IARC.
LONG TERM EXPOSURE TO DUST MAY CAUSE LUNG DAMAGE, POSSIBLE CANCER.
Effects of Overexposure:PROLONGED OVEREXPOSURE TO SOLVENT INGRED. MAY
CAUSE ADVERSE EFFECTS TO THE LIVER, URINARY SYSTEMS. REPORTS HAVE
ASSOCIATED REPEATED AND PROLONGED OVER EXPOSURE TO SOLVENTS WITH
PERMANENT BRAIN AND NER VEOUS SYSTEM DAMAGE.
Medical Cond Aggravated by Exposure:CONTACT WITH CHROME COMPOUNDS(IN
A33110 ONLY) MAY CAUSE ALLERGIC REACTIONS IN SENSITIZED
INDIVIUDALS.
First Aid
First Aid:INHALATION: IF AFFECTED, REMOVE FROM EXPOSURE. RESTORE
BREATHING, KEEP WARM & QUIENT. SKIN: WASH AFFECTED AREA THOROUGHLY
WITH SOAP & WATER. REMOVE CONTAMINATED CLOTHING & WASH BEFORE
RE-USE. EYE: FLU SH WITH LARGE AMOUNT OF WATER FOR 15 MINUTES. GET
MEDICAL ATTENTION. SWALLOWING:GET MEDICAL ATTENTION.
Fire Fighting
Flash Point Method:PMCC
Flash Point:102F,39C
Lower Limits:0.9
Upper Limits:6.0
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM
Fire Fighting Procedures:FULL PROTECTIVE EQUIP, W/SCBA, WATER MAY BE
INEFFECTIVE. IF USED, FOG NOZZLES PREFERABLE. WATER TO COOL CLOSED
CNTNR/PREVENT PRESSUE,AUTOIGNITION, OR EXPLOSION.
Unusual Fire/Explosion Hazard:KEEP CNTNR CLSD. KEEP FR. HEAT, ELECTR
EQUIP, SPARK, FLAME. CLSD CNTNR MAY EXPLODE W/HEAT. APPLICATION TO
HOT SURFACE REQ. SPECIAL PRECAUTION. DURING EMERGENCY*
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Handling
Handling and Storage Precautions:CONTENTS ARE COMBUSTIBLE. KEEP FROM
HEAT/FLAME. CONSULT NFPA CODE. USE APPROVED BONDING, GROUNDING
PROCEDURES. KEEP CLOSED WHEN NOT IN USE.**
Other Precautions:**TRANSFER ONLY TO APPROVED CONTAINERS WITH COMPLETE
& APPROPRIATE LABELS. DO NOT TAKE INTERNALLY. KEEP OUT OF REACH OF
CHILDREN. INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING *
INHALING THE CONTEN TS MAY BE HARMFUL OR FATAL.
Exposure Controls
Respiratory Protection:IF EXPOSURE CANNOT BE CONTROLLED
RESPIRATOR. WHEN SANDING/ABRADING DRIED FILM, WEAR NIOSH/MSHA
APPROVED DUST/MIST RESPIRATOR .
Ventilation:LOCAL EXHAUST PREFERRED. GEN EXHAUST ACCEPTIBLE IF EXPOSURE
MAINTAINED
Eye Protection:SAFETY GLASSES/UNPERFORATED SIDESHIELDS
Work Hygienic Practices:WASH HANDS AFTER USING
Supplemental Safety and Health
USE ONLY WITH ADEQUATE VENTILATION. AVOID BREATHING VAPOR AND SPRAY
MIST. AVOID CONTACT WITH EYES & SKINS.
Chemical Properties
Boiling Pt:B.P. Text:300 TO 448F
Vapor Density:>AIR
Spec Gravity:0.92-1.54
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:32-65%
Stability
Stability Indicator/Materials to Avoid:YES
**SPARKS,OPEN FLAME. HOT FURFACES REQUIRES SPECIAL PRECAUTIONS.
Stability Condition to Avoid:*PREVENTS PRESSURE BUILD-UP/POSSIBLE
AUTOIGNITION/EXPLOSION WHEN EXPOSED TO EXTREME HEAT. ISOLATE FR.
HEAT/ELECT.EQUIP,
Hazardous Decomposition Products:BY FIRE: CARBON DIOXIDE, CARBON
MONOXIDE
Conditions to Avoid Polymerization:*OVEREXPOSURE TO DECOMPOSITON
PRODUCTS MAY CAUSE HEALTH HAZARD. SYMPTOMS MAY NOT BE IMMEDIATELY
APPARENT.
Disposal
Waste Disposal Methods:WASTE MAY BE HAZARDOUS AS DEFINED BY RCRA 40 CFR
261. TEST FOR IGNITABILITY/DETERMINE EPA HAZ WASTE NUMBER. TEST
CHROMIUM OXIDE (A33G110) FOR EXTRACTABILITY. INCINERATE IN APPROVED
FACILITY. DO NOT IN CINERAT CLOSED CNTNR. DISPOSE OF IN ACCORD
W/REGS
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.